6. To get more BY-PASS, turn slotted adjustment screw in spray-head adjuster (Item 49 in parts list) counter-
clockwise. Turning adjuster screw clockwise will decrease the BY-PASS flow.
SPRAY-HEAD ADJUSTER
Left (K245A) Right (K244A) (K253A)
BC 2, BC302 BC1, BC301
FIGURE 2
The BC310 and BC302 units do not use a BY-PASS for 12 and 24 cup brewing. The BY-PASS valve is activated only
when the 36 cup cycle is selected. The BC210 and BC240 models only brew 12 or 24 cups and therefore do not use a BY-
PASS.
THERMOSTAT ADJUSTMENT (See Figure 3)
The BC Brewers are factory set to deliver hot brewing water at 200° F (96° C) when the thermostat knob
is turned on to the full ON position.
THERMOSTAT
BC1, BC2, BC240, BC120
BC301, BC302
Figure 3
The water temperature, at the spray head, should be between 195° F-203
0
F with the thermostat knob at its maximum
clockwise position. If adjustment is necessary, proceed as follows:
1. To RAISE water temperature, turn temperature control knob to its maximum clockwise position. Remove the knob and
locate slotted adjustment screw inside hollow thermostat shaft. Using a narrow-bladed screwdriver, engage slotted
adjustment screw and turn it 1/4 turn counter-clockwise. The thermostat will cut in and the Green ready light will go
off. When Green ready light comes on after a few minutes, measure temperature and repeat if necessary.
5