CENTURY 2000-IT, COFFEE BREWING EQUIPMENT Cecilware sells value... Worldwide 43 -05 20th Avenue, Long Is
10WARMER TIMER WARMER TIMER ON/OFF Description – The Warmer Timer feature allows the user to set the maximum length of time a brew remains fresh whi
11ADJUST SECONDS ADJUST SECONDS DAY HH:MM:## Description – The Adjust Seconds function allows the user to adjust (set) the systems Real-Time-Clock S
12ERROR MODE Description – The main function of Error Mode is report any system malfunctions and to disable the unit The system must be “powered dow
13C-2003G-IT FRONT OPEN VIEW 123451817161513121167891014
14TOP CABIN OPEN VIEW 2423292825261920212232313027
15 PARTS IDENTIFICATION FOR C-2003G-IT, C-2003LG-IT, C-2003RG-IT ITEMSPARE PARTS P/N QTY DESCRIPTION 1 * NG3
16 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any intern
17 SPECIAL COMPONENTS TEST AND ADJUSTMENTS 1) WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin) Turn power off from touchpad. I
18 5) CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin) Drain The Water Tank To Just Below The Level Of The Dispense Valves. Re
19 #1100WCECILWARE CORPORATIONELECTRICAL DIAGRAM C-2003G-IT 120V (3 BURNERS)L1BERG CONNE
2SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. C-2003G-IT C-2003RG-IT C-2003LG-IT Volts 120 120 120 Watts 1,800 1,800 1,800 Amps 15 15 15 Wall
3 FEATURES AND BENEFITS OF THE DIGITAL, MEMBRANE CONTROL TOUCH PAD BREWER 1. 100% Solid State Control for improved reliability. 2. Modular desi
4 INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data
5NG34A-ECAUTIONHOT WATERD:\1-Milt\Labels & Logos\Techno copy.tif PROGRAMMING INSTRUCTIONS The following is a Functio
6 MODES OF OPERATION – DESCRIPTIONS Initialization Mode: The following screen signifies the presence of this mode: CECILWARE &&&&&a
7Brewing State BREWING DDD K MM:SS HH:MMP Description – This screen is displayed when a Brew Cycle is in progress. The time remaining in the B
8SERVICE MODE Description – The main function of Service Mode is to give qualified personnel the ability to configure the system to meet the require
9INFUSION TIME - OPTIONAL INFUSION TIME ## SECONDS Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot