To prevent lime buildup, especially in hard water areas, remove and clean spray head cap and spray head disc frequently. To clean swivel
valve (see III. 2) loosen nut and remove spray arm assembly from urn. Remove sediment by inserting a pipe cleaner through small hole in
valve. If maximum setting of timer (18. III. 3) fails to deliver enough water, check water pump (28).
FOR QUALIFIED SERVICE PERSONS ONLY
CAUTION: DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL REPAIRS.
IF WATER FAILS TO HEAT:
1. Check line fuse or circuit breaker. Replace or reset if necessary.
2. Make sure thermostat is in ON position. If thermostat pilot light does not come on, replace thermostat (21, III. 3). (Refer to instructions
below.) If pilot light is on, measure continuity between terminals 1 and 2 of thermostat, and between terminals 3 and 4. (See III. 6) If a
resistance Is measured, replace thermostat.
3. If thermostat is okay, check wiring and repair if necessary; if wiring is okay, check heater resistance; if high or infinite, replace as follows:
REPLACING HEATER (See III. 3):
1. Shut off power and disconnect water supply at elbow (22,111.3). Drain urn.
2. Remove one coffee gauge glass (37), faucet (36), shank (37), and liner (12).
3. Tilt urn and disconnect wires to heater (34).
4. Remove socket head screw and heater flange and lift heater out.
5. Install new heater and reassemble urn.
6. Repeat priming instructions on page 2. CAUTION: DO NOT TURN ON THERMOSTAT UNTIL URN IS PRIMED.
REPLACING THERMOSTAT (FE200, FE250, FE300):
1. Shut off power, disconnect water supply, and drain urn.
2. Tilt urn and check wiring underneath before removing thermostat. If wiring seems to be in good condition, proceed as follows:
3. Remove thermostat knob (33, III. 3) and two screws holding thermostat in place.
4. Disconnect wires from thermostat.
5. Unscrew packing nut and pull out thermostat bulb.
6. Install new thermostat.
7. Repeat priming instructions on page 2. CAUTION: DO NOT TURN ON THERMOSTAT UNTIL URN IS PRIMED.
REPLACING THERMOSTAT (All Other Models): Thermostat is located in side box instead of skirt of urn. Lift off side box door to gain
access to thermostat; then follow instructions above.
IF WATER FROM COLD WATER SUPPLY LINE DOES NOT ENTER URN:
1. Check water supply to external shut-off valve and water strainer (23, III. 3).
2. Check fuse (30) on front of side box and replace if necessary.
3. If water supply and fuse are okay, remove fuse and lift off side box door. Remove timer (18), exposing terminal block (16) (see III. 5)
and electrical wiring.