OPERATING ENVIRONMENTAL TEMPERATURE:
Mininum Ambient Temperature: 32º F [0º C]
NOTE: The appliance is not suitable for unsupervised use by young children or aged or infirm persons,
according to national standards.
UNPACKING AND ASSEMBLY:
The LTB- 303, 505, 103, 105 is shipped with a set of short adjustable legs mounted on and an
additional set of 4" legs with drip tray, funnel, and a water inlet fitting. Install 4" legs to use drip tray.
The LTB-1010 and LTB-1010 Twin is shipped with a set of short adjustable legs mounted on, a
funnel, and a water inlet fitting.
WATER INLET CONNECTION:
HIGHLY RECOMMENDED: A water shut-off valve and a water filter, preferably a combination charcoal/
phosphate filter, to remove odors and inhibit lime and scale build up in the machine.
Note: In areas with extremely hard water, a water softener must be installed in order to prevent a
malfunctioning of the equipment and in order not to void the warranty.
The tea dispenser is equipped with a ¼" flare water inlet fitting which is located in the back of the unit.
Connect the ¼" dia. Copper waterline to the ¼" flare water inlet fitting of the valve.
This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes
having jurisdiction. In addition:
1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the
unit) so that the machine can be moved for cleaning underneath.
2. An approved back flow prevention device, such as a double check valve to be installed between
the machine and the water supply.
3. For use of machine outside the United States of America, connection to water supply mains
should comply with the national "Model Water Byelaws"
NOTES:
1. The machine is equipped with a low temperature lockout system and will not brew until the hot
water tank is filled with water and has reached the proper brew temperature of 195°f. To test
machine with cold water, leave heater switch off.
2. For Portable [-P] units: As the machine brews and dispenses tea, the pump will automatically draw
water from the water bottle to maintain tank full. Be sure to keep a second full bottle of water next to
the machine, so that when one bottle runs out of water you can transfer the hose to the next bottle.
3. For Portable [-P] units: The pump needs to be reprimed whenever the pump priming button lights up:
a) If the bottle runs out of water.
b) If the hose inside the bottle is pulled out of the water while the pump is drawing water, causing airlock.
4. For Portable [-P] units: From time to time after the tank is full, and machine has not been used for
some time, the priming button will light up, indicating that the pump is airlocked, due to pressure build
up. When the brew button is pressed, it releases the trapped air between the pump and the dispense
valve, and normal operation will resume.
After the tank is full the pump will stop drawing water, it will not start drawing water again until the
brew button is pressed causing the dispense valve to open up and dispense water.
MODEL NO.
LTB-303C, 505-IT, LTB-103, 105
* LTB-PORTABLE - OPTIONAL
LTB-303, 505, LTB-103, 105
LTB-1010, LTB-1010 DUAL
VOLTS
120
240
240
PHASE
1
1
1
HZ
60
60
60
WATTS
KW
1.8
3.0
4.8
NO. OF
HEATERS
1
1
2
AMPS
15
12.5
20
RECEPTACLE
NEMA NO.
5-15R
6-20R
6-30R
POWER
CORD
5-15P [2 WIRES+GND]
6-20P [2 WIRES+GND]
6-30P [2WIRES+GND]
CIRCUIT
BREAKER AMPS
15A
20A
30A
ELECTRICAL SPECIFICATIONS